Saluki S3302SC handheld/ portable spectrum analyzer is a 9GHz handheld instrument. It provides multi-functions to fullfill different requirements from users. S3302SC handheld spectrum analyzer has a compact design which is very suitable for on-site measurement. S3302 series handheld spectrum analyzer can be applied to the signal and equipment test in aerospace, microwave and satellite communications, wireless communications, radar surveillance, electronic warfare and electronic surveillance, precision-guided and other industries.
Specifications of S3302SC Handheld/ Portable Spectrum Analyzer
Parameter | Specifications | |||
Frequency Range | S3302SC | |||
9kHz - 9GHz | ||||
Tuning Resolution | 1Hz | |||
Reference Frequency | Nominal Frequency | 10MHz | ||
Aging Rate | ± 0.5ppm / Year | |||
The Initial Frequency Accuracy | ± 0.3ppm | |||
Temp. Stability | ± 0.1ppm(-10 - 50°C, with respect to 25°C) | |||
Scan Time | Range | 10μs - 600s (Zero Span) | ||
Accuracy | ± 2.00% (zero span) | |||
Frequency Readout Accuracy | Frequency Readout Accuracy = ± (frequency readout × frequency reference error + 2% × span + 10% × resolution bandwidth) | |||
Sweep Width | Range | 100Hz - Max. Frequency. 0Hz | ||
Accuracy | ± 2.0% | |||
Resolution Bandwidth | 1Hz - 10MHz (step 1-3 times) | |||
Video Bandwidth | 1Hz - 10MHz (step 1-3 times) | |||
SSB phase noise (CF = 1GHz) |
<-108 dBc / Hz @ 10kHz offset | |||
<-112 dBc / Hz @ 100kHz offset | ||||
<-118 dBc / Hz @ 1MHz offset | ||||
<-129 dBc / Hz @ 10MHz offset | ||||
Residual Response | Preamplifier Off | 10MHz - 9GHz | <-82dBm | |
Preamplifier On | 10MHz - 9GHz | <-95dBm | ||
Exception Frequency: 3.2GHz | ||||
Displayed Average Noise Level | Preamplifier Off | 10MHz - 3GHz | <-140dBm | |
3GHz - 9GHz | <-138dBm | |||
Preamplifier On | 10MHz - 3GHz | <-160dBm | ||
3GHz - 9GHz | <-157dBm | |||
Second Harmonic Distortion (Attenuation 0dB, -30dBm input signal) |
S3302 SC | |||
<-65dBc | ||||
Absolute Amplitude Accuracy (20°C - 30°C, 30 minute warm-up) |
10MHz - 13GHz: ± 1.8dB 13GHz - 40GHz: ± 2.3dB |
|||
Input Attenuator | 0dB - 50dB, 10dB step | |||
Max. Safe Input Level | S3302 SC | |||
+ 27dBm, typical values (>10dB attenuation) | ||||
+ 20dBm, typical values (<10dB attenuator) | ||||
+ 10dBm, typical values (preamplifier on) | ||||
Reference Level | Range: -120dBm - +30dBm | |||
Conversion Uncertainty: ± 1.20dB | ||||
VSWR of Input Interface | Under the condition of reference level >0dBm, attenuator defaults | |||
<1.5: 1 typical (50MHz - 20GHz) | ||||
<2.0: 1 typical (20GHz - 44GHz) | ||||
Other Interface | 10MHz reference input / output | BNC Connector (F) | ||
External trigger input | ||||
IF output | ||||
GPS antenna input | ||||
Battery Life | About 3hrs | |||
Power Consumption | <30W (no battery charging) | |||
Operating Temp. | -10°C - +50°C | |||
Storage Temp. | -40°C - +70°C | |||
Weight (without batteries) | About 4.5kg | |||
Dimension | 314 (W) × 218 (H) × 91 (D) mm | |||
(excluding the handle, brackets) | ||||
338 (W) × 218 (H) × 100 (D) mm | ||||
(including a handle, bracket) | ||||
Electromagnetic Compatibility | Comply with 3.9.1 GJB3947A-2009 |
Standard Pack of S3302SC Handheld/ Portable Spectrum Analyzer
No. | Item |
1 | S3302SC Main Machine |
2 | Power Cord |
3 | User Manual |
4 | Power Adaptor |
5 | Battery |
6 | USB Cable |
7 | Soft Pack Bag |
Options of S3302 Series Handheld/ Portable Spectrum Analyzer
Option No. | Item |
S3302-05 | Programming manual |
S3302-06 | Power adapter |
S3302-07 | Rechargeable lithium-ion battery |
S3302-08 | CAT5 LAN Cable |
S3302-09 | Micro SD card |
S3302-10 | GPS option |
S3302-11 | USB power meter option |
S3302-12 | S87230 USB power continuous wave power sensor (9kHz - 6GHz) |
S3302-13 | S87231 USB power continuous wave power sensor (10MHz - 18GHz) |
S3302-14 | S87232 USB power continuous wave power sensor (50MHz - 26.5GHz) |
S3302-15 | S87233 USB power continuous wave power sensor (50MHz - 40GHz) |
S3302-16 | Interference analyzer option |
S3302-17 | AM/FM/PM analyzer option |
S3302-18 | Channel scanner option |
S3302-19 | List sweep function |
S3302-20 | Zero span IF output |
S3302-21 | S89101A antenna (10kHz - 20MHz) |
S3302-22 | S89101B antenna (20MHz - 200MHz) |
S3302-23 | S89101C antenna (200MHz - 500MHz) |
S3302-24 | S89101D antenna (500MHz - 4GHz) |
S3302-25 | S89401 antenna amplifier (10kHz - 4GHz?N(f)) |
S3302-26 | S89901 antenna (1GHz - 18GHz, N(f)) |
S3302-27 | S89902 antenna (18GHz - 40GHz, 2.92mm(f)) |
S3302-28 | Functional Bag |
S3302-29 | Backpack |
S3302-30 | Carrying case (for safety carrying) |
S3302-31 | S89901 antenna handle |
S3302-32 | S89902 antenna handle |
S3302-33 | Signal analyzer |
S3302-34 | Field strength option |
S3302-35 | Tracking generator (100kHz - 4GHz) |
S3302-36 | Tracking generator (100kHz - 6.5GHz) |
S3302-37 | Tracking generator (100kHz - 9GHz) |
S3302-38 | Orientation analysis option |
S3302-39 | Coverage map option |
S3302-40 | Charger of power supply by vehicle |
S3302-41 | Portable omnidirectional antenna (700MHz - 2.7GHz) |
S3302-42 | 700MHz - 4GHz directional antenna |
S3302-43 | 700MHz - 6GHz directional antenna |
S3302-44 | 680MHz - 10GHz directional antenna |
S3302-45 | 680MHz - 20GHz directional antenna |
S3302-46 | 400MHz - 4GHz directional antenna |
S3302-47 | 400MHz - 6GHz directional antenna |
S3302-48 | 380MHz - 10GHz directional antenna |
S3302-49 | 380MHz - 20GHz directional antenna |
S3302-50 | External electric compass |
S3302-51 | 680MHz - 6GHz omnidirectional antenna |
S3302-52 | 300MHz - 8GHz omnidirectional antenna |
S3302-53 | VHF/UHF portable antenna |
S3302-54 | 700MHz - 4GHz passive directional antenna |
S3302-55 | 700MHz - 6GHz passive directional antenna |
S3302-56 | 680MHz - 10GHz passive directional antenna |
S3302-57 | 680MHz - 18GHz passive directional antenna |
S3302-58 | 680MHz - 25GHz passive directional antenna |
S3302-59 | 680MHz - 35GHz passive directional antenna |
S3302-60 | N/SMA-JJ RF cable (2m) |
S3302-61 | N/SMA-JJ RF cable (1m) |